这里是产品名称这里是产品名称这里是产品名称这里是产品名称
1/1
Number of views:
1000

DAM-3944A

DAM-3944A is a 4-channel signal relay output module, in which, it has 3-channel C-type relay and 1-channel A-type relay, and it supports the RS485 communication interface and standard ModbusRTU protocol.
Market price
0.0
Number of views:
1000
Quantity
-
+
1
Product description

Digital Output

Channel

3-Channel C-type signal relay and 1-Channel A-type signal relay

Contact Material

Ag+Au clad (silver+gold cladding)

Rated Control Capacity

(Resistive Load) Note 1

2A, 30V DC

Contact Maximum Allowable

Current (Resistive Load)

2A

Contact Maximum Switching

Voltage (Resistive Load) Note 2

220V DC or 220V AC

Minimum Applicable Load

(Resistive Load)

10µA 10mV DC

Relay Off Time

4ms (max)

Relay On Time

4ms (max)

Mechanical Life

More than 100 million times (on-off frequency 180 times/min)

Electrical Life

More than 100,000 times (under 2A 30V DC resistive load),

more than 500,000 times (under 1A 30V DC resistive load)

(on-off frequency 20 times/min)

Others

Communication Interface

RS485

Baud Rate

1200~115200bps

Data Communication Rate Note 3

Maximum 180 times/second (single module, under 115200bps)

Maximum 24 times/second (single module, under 9600bps)

Maximum 3 times/second (single module, under 1200bps)

The above rate values are only reference values, and are

also related to factors such as the length of the 485 bus line

and the number of access modules on site.

Watchdog

Support dual watchdog

Supply Voltage

+10V30VDC

Power Protection

Power reverse protection

Power Consumption

Rated 2.4W @ 24VDC

Operating Temperature

-10~+70

Storage Temperature

-20~+85

 

Note

1. Resistive Load: The maximum value of all parameters of the relay is realized when the load is resistive load. Resistive load means the load that iodine tungsten lamp, incandescent lamp, resistance furnace, oven, electric water heater, etc. will not cause voltage and current phase changes.

2. Contact Maximum Switching Voltage: this value is the maximum value when the load is a resistive load, and supports DC and AC voltage. If the load is a capacitive load or an inductive load, this indicator may be reduced.

3. Data Communication Rate: This parameter refers to the communication speed between the MCU controller and the host computer, which belongs to the theoretical maximum value. The communication rate will also be affected by the length of the field wiring, the number of loaded modules, the programming architecture of the host computer, and the hardware capabilities of the CPU.

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table
There is currently no content to display
Please add data record on website background.
There is currently no content to display
Please add data record on website background.

©2019 Beijing Art Technology Development Co., Ltd., All rights reserved  京ICP备09023590号  Powered by www.300.cn